ECG90A 12-channel 12-lead +PC Software
Introduction
ECG90A is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in: recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for "Lead off" or "Lack of paper", optional interface languages(Chinese/English), case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Particular and high-accurate digital filter eliminates baseline drift, no distortion to ECG waveform, greatly enhances anti-baseline drift capacity, convenient for waveform judgment.
3)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
4)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
5)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
6)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
7)Optional SD card stores up to 100 cases, which is convenient for doctor to review case and statistic.
8)In review mode, case waveform stored can be checked, measurement parameter and diagnosis information can be automatically analyzed.
9)Two languages(Chinese or English) interface and report.
10)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, collect real-time data to the software for analyzing and printing the report, and old cases stored in Electrocardiograph can be uploaded to PC.
11)Power supply: AC/DC, and in optimal DC state, built-in rechargeable lithium battery can continuously work for 4-hour, print up to 90-minute and 150-ECG, which meets the requirements of visiting a patient at home and body examination. Rechargeable lithium battery is detachable, which is convenient for user to replace and charge in any time.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 50mm(W)×20m(L)
Sampling frequency: 1000Hz
Polarizing voltage: ±500mV
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 6.25, 12.5, 25, 50mm/s, ±5%
Manual: 6.25, 12.5, 25, 50mm/s, ±5%
Power supply: DC 12V adapter, 7.4V/2000mAh rechargeable lithium battery
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
A power adapter
ECG100G single channel 12-lead without Software
Introduction
ECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal printing system, prompting for "Lead off" or "Lack of paper", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate.
Function
1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.
6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 50mm(W)×20m(L)
Sampling frequency: 800Hz
EMG interference filter: 35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed: 25, 50mm/s, ±5%
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/2000mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
Certification
CE,FDA
ECG300G 3-channel 12-lead +PC Software
Introduction
ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: <15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 80mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
A lead cable
ECG electrode
A thermal recording paper
A power cord
An earth wire
A user manual
ECG-Sync software+USB cable
Physical characteristic
Dimension: 315mm(L) × 215mm(W) × 77mm(H)
Weigh: 1.6Kg
ECG1200G 12-channel 12-lead + Software,Touch screen
Introduction
ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 210mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Power supply:
AC: 100V~240V(50/60Hz)
DC: 14.8V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and storage environment
Temperature: -40℃~+55℃
Relative humidity: ≤95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 340mm(L) × 320mm(W) × 85mm(H)
Weigh: 3.2Kg
Shipping
1. We will ship the item within 2 days after receiving your payment.All orders will be
shipped from China warehouse by China Post 2-4 weeks Arrival.
US buyer,ship from Illinois warehouse,fast delivery.
2. All items will be shipped to buy's ebay address. Please check your ebay address is right.
3.The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of it as you want us to,so that it is easier for you to clear the custom.
International Buyers - Please Note:
* Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
* Please check with your country customs office to determine what additional costs will be prior to bidding
Terms of Sale
Returns:
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 year warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
Buy safe products
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved
About Us
CONTEC Medical System-----Focusing on research, manufacture and distribution of medical equipment,
CONTEC Medical System was founded in 1992 as a professional medical equipment producer.
At present,there are more than 1200 employees in our company .Our product lines cover a wide range of 13 categories,and have been distributed over 30 countries.
We are the manufacture of medical equipment for more than 20 years, main products include ECG machine,
Patient monitor,EEG machine,pulse oximeter,Fetal doppler,Blood pressure monitor and so on..
Contact Us
We are Professional Manufacturer--CONTEC MEDICAL SYSTEMS CO.,LTD
Looking forward to establishing a successful business relationship with you.
Contact Person:Vivian Zhang
Only English User manual,Please contact us if you need other language version.