-40%
Fluke 712B RTD RESISTANCE TEMPERATURE DETECTOR CALIBRATOR SIMULATE 13 TYPES
$ 712.27
- Description
- Size Guide
Description
SERIOUS BIDDERS ONLY!PLEASE READ THE DESCRIPTION CAREFULLY!
You are bidding on the following:
*** BRAND NEW***
FLUKE 712B RTD (RESISTANCE TEMPERATURE DETECTOR) DUAL INPUT TEMPERATURE CALIBRATOR SIMULATE 13 RTD TYPES & RESISTANCES
Model #: 712B
Item Details:
Manufacturer:
Fluke
Description:
luke 712B RTD Calibrator provides highly accurate, easy-to-use, single-function RTD temperature calibration
Fluke 712B RTD Calibrator is a handheld, battery-operated instrument that measures and sources a variety of RTD types and resistances. It also includes an isolated channel to measure 4-20 mA whiles sourcing a temperature signal. It offers configurable 0% and 100% source settings for quick 25% linearity checks. It also provides linear ramp and 25% step auto ramp functionality based on 0% and 100% settings.
Add to that dual inputs, an easy to view backlit display, plus the ability to memorize settings at power down for easy restart make the 712B the ideal test tool for temperature calibration professionals who want a highly accurate, easy-to-use, single function RTD temperature calibrator.
Other useful features:
Dual inputs and backlit display for easy interpretation of measurements
Remembers power down settings to easily restart tests when powered up
Provides linear ramp and 25% step auto ramp based on 0% and 100% settings
Provides one-year and two-year specifications and traceable certification of calibration
Key features
Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
Measures and simulates 13 different RTD types and resistance
Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
Comes with a magnetic hanging tool designed in for convenient hands-free operation
Features configurable 0% and 100% source settings for quick 25% linearity checks
Specifications: Fluke 712B RTD Calibrators
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals
30 V
Operating temperature
-10°C to 50°C
Storage temperature
-30°C to 60°C
Operating altitude
2,000 m
Storage altitude
12,000 m
Relative humidity (% RH operating without condensation)
Non condensing
90% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
(Without condensation)
Vibration requirements
MIL-T-28800E, Class 2
Drop text requirements
1 m
IP Rating
IEC 60529: IP52
Electromagnetic environment
IEC 61326-1, Portable
Safety
IEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply
4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L)
52.5 x 84 x 188.5 mm
Weight
515 g
DC mA Measurement
Resolution
0-24 mA
Range
0.001 mA
Accuracy (% of reading + counts)
0.010% + 2 μA
Temperature coefficient
± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C)
Ohms Measurement
Ohms range
Accuracy (% of reading +counts)
0.00 Ω to 400.00 Ω
0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω
0.015% + 0.5 Ω
Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications.
Temperature coefficient
±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C)
Ohms Source
Ohms range
1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Excitation current from measurement device
0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts)
0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Resolution
0.00 Ω to 400.00 Ω
0.01 Ω
400.0 Ω to 4000.0 Ω
0.1 Ω
Temperature coefficient
± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms
RTD Input and Output
RTD Type (α)
Range (°C)
Measure (°C)
Source (°C)
1-year
2-year
Source current
1-year
2-year
10 Ω Pt (385)
-200 to 100°C
1.5°C
3°C
1 mA
1.5°C
3°C
100 to 800°C
1.8°C
3.6°C
1 mA
1.8°C
3.6°C
50 Ω Pt (385)
-200 to 100°C
0.4°C
0.7°C
1 mA
0.4°C
0.7°C
100 to 800°C
0.5°C
0.8°C
1 mA
0.5°C
0.8°C
100 Ω Pt (385)
-200 to 100°C
0.2°C
0.4°C
1 mA
0.2°C
0.4°C
100 to 800°C
0.015%
+0.18°C
0.03%
+0.36°C
1 mA
0.015%
+0.18°C
0.03%
+0.36°C
200 Ω Pt (385)
-200 to 100°C
0.2°C
0.4°C
500 μA
0.2°C
0.4°C
100 to 630°C
0.015%
+0.18°C
0.03%
+0.36°C
500 μA
0.015%
+0.18°C
0.03%
+0.36°C
500 Ω Pt (385)
-200 to 100°C
0.3°C
0.6°C
250 μA
0.3°C
0.6°C
100 to 630°C
0.015%
+0.28°C
0.03%
+0.56°C
250 μA
0.015%
+0.28°C
0.03%
+0.56°C
1000 Ω Pt (385)
-200 to 100°C
0.2°C
0.4°C
250 μA
0.2°C
0.4°C
100 to 630°C
0.015%
+0.18°C
0.03%
+0.36°C
250 μA
0.015%
+0.18°C
0.03%
+0.36°C
100 Ω Pt (3916)
-200 to 100°C
0.2°C
0.4°C
1 mA
0.2°C
0.4°C
100 to 630°C
0.015%
+0.18°C
0.03%
+0.36°C
1 mA
0.015%
+0.18°C
0.03%
+0.36°C
100 Ω Pt (3926)
-200 to 100°C
0.2°C
0.4°C
1 mA
0.2°C
0.4°C
100 to 630°C
0.015%
+0.18°C
0.03%
+0.36°C
1 mA
0.015%
+0.18°C
0.03%
+0.36°C
10 Ω Cu (427)
-100 to 260°C
1.5°C
3°C
1 mA
1.5°C
3°C
120 Ω Ni (672)
-80 to 260°C
0.15°C
0.3°C
1 mA
0.15°C
0.3°C
50 Ω Cu (427)
-180 to 200°C
0.4°C
0.7°C
1 mA
0.4°C
0.7°C
100 Ω Cu (427)
-180 to 200°C
0.2°C
0.4°C
1 mA
0.2°C
0.4°C
YSI400
15 to 50°C
0.2°C
0.4°C
250 μA
0.2°C
0.4°C
1. Sensor inaccuracies not included.
2. Resolution: 0.1°C.
3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications.
4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range).
5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source.
6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.
Included Accessories:
AC175 alligator clips (2 sets)
TL75 test leads (2 sets)
754-8016 alligator clips (1 set)
Stackable test leads (1 set)
4 AA alkaline batteries
Magnet Strap TPAK
712B/714B Safety Sheet
712B Quick Reference Guide
712B Users Manual (available on Fluke’s website)
Condition:
Brand New
Auction Details:
Shipping:
All
domestic
packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
Shipping to Hawaii and Alaska would be extra, and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.
Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior bidding.
Goods will be dispatched the latest in
2
business days.
Goods will be shipped out after the holidays and weekends.
No local pick
ups accepted at this time, unless otherwise stated in the auction
Shipping costs are set at that price to cover some of our costs and packaging and handling fees as well as some of the ebay and paypal fees which add to about 13% of the total end price. Please don't email us to negotiate about the shipping costs. We are extremely busy, so we might not answer your emails.
Shipping and handling fees are not negotiable, by bidding on this item the buyer agrees to pay for all the shipping costs
We ship to any destination in the world.
INTERNATIONAL BUYERS:
The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
California buyers are subject to pay 9% tax.
International buyers are responsible for all tax and custom duty charges outside the country.
Payment:
U.S. Buyers:
Credit cards through PayPal
Please note that we can't accept direct credit card payments at this time
International Buyers:
PayPal or Wire
Payment is due within 6 days of auction closing.
If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on eBay.
Terms & Conditions:
After the auction is closed,
auction winners should contact us regarding any questions or requests.
After the auction is closed, payment should be received within 6 days.
Buyer has 14 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs both ways.
Shipping and handling charges are not returnable
Items will be replaced or exchanged in case of DOA
If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
Contact Information:
Please use ebay message