-40%
GE MAC 2000 Resting ECG Analysis System
$ 1848
- Description
- Size Guide
Description
GE MAC 2000 Resting ECG Analysis System SpecificationsECG Interpretation:
Marquette 12SL ECG Analysis Program for Adults and Pediatrics.
Computerized Measurements:
12-lead analysis.
ECG Analysis Frequency:
500 or 1,000 samples/second/channel.
Digital Sampling Rate:
16,000 samples/second/channel.
Pace Sampling Rate:
75K samples/second/channel.
ECG On-Screen Preview:
On-screen preview of acquired 10 second ECG waveform.
Acquisition Mode:
Provides 10 seconds of instantaneous ECG acquisition.
Dynamic Range:
AC Differential +/- 5 mV, DC offset +/- 300 mV.
Resolution:
4.88 μV +/- 1% per LSB at 500SPS.
Frequency Range:
0.04 to 150 Hz.
Low Cutoff Frequency:
ADS Off:
0.04 Hz.
ADS On:
0.56 Hz.
High Cutoff Frequency:
Configurable at 20 Hz, 40 Hz, 100 Hz, or 150 Hz.
Common Mode Rejection:
Greater than 135 dB (with 50/60 Hz filter on).
Input Impedance:
Greater than 10 Ω at 10 Hz.
Patient Leakage:
Less than 10 μA (Normal Condition), less than 50 μA (single Fault Condition).
Lead Detection:
All disconnected lead detection except RL and RA.
Heart Rate Meter:
30 to 300 BPM.
Operating System:
Microsoft Windows CE 6.0.
Start-Up Time:
Less than 30 Seconds.
Display:
Type:
7" color TFT display with support of minimum 32K colors.
Resolution:
WVGA resolution 800 x 480.
Data:
Heart rate, patient ID, clock, battery power indicator, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display.
Electrical:
Power Supply:
Internal AC/DC or battery operation.
Input Voltage:
100 to 240 VAC +/- 10%.
Input Current:
Maximum 1.5A in voltage range 115V to 230V AC.
Input Frequency:
47 to 63 Hz.
Battery Type:
Replaceable and rechargeable, Lithium Ion.
Battery Capacity:
14.54V nominal voltage at 3.5 AH +/- 10%. 150 single page resting ECG recordings or 6 Hours (typical) of continuous monitoring without printing, at a minimum.
Battery Charge Time:
Approximately 3.5 hours after low battery shut down (with device off) to 90% full capacity.
Dimensions:
200 mm x 390 mm x 330 mm.
Weight:
Approx. 5 kg including battery, without paper.
Environmental Conditions:
Operating Temperature:
10 degrees C to 40 degrees C.
Transport/Storage Temperature:
-40 degrees C to 70 degrees C.
Operating Humidity:
20% to 90% RH non-condensing.
Transport/Storage Humidity:
15% to 95% RH non-condensing.
Operating Pressure:
700 to 1060 hPa (Altitude Range: 3010.9 to - 381.9 meters).
Transport/Storage:
500 to 1060 hPa (Altitude Range: 5570 to - 380 meters).
TERMS AND CONDITIONS
SDI Medical Consultants
CONDITION:
1. Overall Condition:-
Good
2. Physical Condition: Good cosmetically and Functional ? ask if you have questions.
3. Working Condition: Used and or Manufacturer Refurbished in working condition. Offered for sale AS IS WHERE IS
BUYER:
ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND, THERE WILL BE NO REFUND. .
Accessories: Comes with everything you see in picture.
TERMS :
PAYMENT: PAYPAL, WIRE TRANSFER
If need more info send a request
No warranty, offered for all sales and all are AS IS WHERE IS
All international sales are final!
Please note that shipping charges are based on weight & meant for 48 US states
International Customers: shipping charges would be billed separately and additional
Shipping Carriers: various; preferred are UPS and FedX
Buyers are responsible for all customs charges inclusive of any and all taxes and duties.
DISCLAIMERS:
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, you will need to verify your status as an authorized purchaser of this item before bidding on or purchasing the item."
2. This item is Being Sold in AS IS condition & the seller assumes no responsibility for the proper or improper use of the product. If the item is to be used in conjunction with patient care and/or diagnosis, it is responsibility of the buyer to get proper certifications/licenses for the use of the item. It would be highly recommended and wise to have a professional completely check the product for its calibration, condition, and performance and safety parameters before actual use for patient care and/or diagnosis.
SHIPPING TERMS:
Products are carefully packed to minimize in-transit damage, all shipments should be carefully examined upon receipt and if product is damaged, you must document the nature and extent of the damage and immediately contact SDI Medical Consultants.
2. If concealed loss or damage is discovered, buyer must retain all packing materials and immediately notify SDI Medical at 619-267-1391, requesting an inspection.