  • Features: Printer
  • Number of Leads: 12
  • Mounting: Portable
  • Operation: Digital
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: China
  • Condition: New
  • Refund will be given as: Money Back
  • Brand: CONTEC
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • MPN: Does Not Apply
  • ECG & EKG Machine Type: Electrocardiograph
  • Bundle Listing: Yes
  • Number of Channels: 6
  • Item must be returned within: 60 Days
  • Model: ECG600G
  • Application: Resting

    Description

    3/6 lead TOUCH SCREEN ECG EKG Electrocardiograph Printer PC software
    Introduction
    ECG600G is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.
    Function
    1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
    2)Real-time and continuously record clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
    3)Full-digital filter design, anti-baseline drift, AC and EMG interference.
    4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
    5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
    6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
    8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.
    9)Display of real-time 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.
    10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes.
    11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform).
    12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time.
    13)Store more than 1000 cases, convenient for case review and statistic.
    14)Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakh, Russian, Ukrainian, Vietnamese, Serbian, Slovenian and Slovak) interface and report.
    Performance
    Input mode: floating and defibrillation protection
    Input impedance: ≥2.5 MΩ
    Patient leakage current: <10 µA
    Frequency response:
    Rated input amplitude    Input frequency and waveform    Relative output response
    1.0    0.67Hz~40Hz, Sine wave    ±10%a
    0.5    40Hz~100Hz, Sine wave    +10 %, -30 %a
    0.25    100Hz~150Hz, Sine wave    +10 %, -30 %a
    0.5    150 Hz ~ 500 Hz, Sine wave    +10 %, -100 %a
    1.5    ≤1Hz,200ms, Triangle wave    +0 %, -10 %b
    a relative to 10Hz   b relative to 200 ms
    Time constant:≥ 3.2s
    CMRR: >105dB
    Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter
    Recording way: thermal printing system
    Specification of recording paper: 110 mm(W)×20 m(L) high-speed thermal paper
    Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%
    Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV
    Recording mode: auto mode, rhythm mode and manual mode
    Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
    Safety classification: Class I, type CF defibrillation-proof applied part
    Polarization resistance voltage: ±610mV
    Noise level: ≤12 µVp-p
    ECG signal input sampling frequency: 32 kHz
    Waveform data processing sampling frequency: 1 kHz
    Sampling accuracy: 24-bit
    The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected
    Pacing detection channel: standard II
    Accuracy of input signal: ±5%
    Amplitude quantization: ≤5µV/LSB
    Interchannel time deviation: <100 µs
    Power supply:
    AC: 100V~240V(50/60Hz)
    DC: 7.4V/3500mAh rechargeable lithium battery
    Degree of protection against ingress of liquid: IPX0
    Working mode: continuous working
    Accessories
    Standard configuration:
    A lead cable
    A limb electrode
    A chest electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    Physical characteristic
    Working environment
    Temperature: 5℃~40℃
    Relative humidity: 25%~95%(non-condensing)
    Atmospheric pressure: 700 hPa~1060 hPa
    Transport and storage environment
    Temperature: -20 ℃~+55 ℃
    Relative humidity: ≤95%
    Atmospheric pressure: 500 hPa~1060 hPa
    Dimension: 315mm(L)×215mm(W)×92mm(H)
    Weight: 1.7Kg
    Certification
    SFDA, CMC, CE.