-40%

Wireless Stress ECG/EKG Analysis System,CONTEC8000S Exercise stress ECG Test

$ 157.87

Availability: 100 in stock
  • Application: Stress Test
  • Brand: CON TEC
  • Item must be returned within: 60 Days
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • MPN: 69450401
  • Model: CONTEC8000S

    Description

    12 Lead wireless Stress ECG system, ECG Workstation, CONTEC8000S
    Introduction
    The Stress ECG Analysis System is consist of sampling hardware device, special software system and exercise equipment. Its functions include 12 leads ECG synchronously sampling, and data storage, ST segment analysis, ECG review in dynamic/static/superimposed during the whole exercise process, and trend chart analysis of multiple parameters, multiple printable report, etc. The patient's exercise state can be recorded timely and accurately, which reflects patient’s heart function, providing reliable data for doctors in diagnoses.
    Features
    1. Print ECG waveform in real-time during sampling process, record and save ECG data of whole process.
    2. Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data.
    3. Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference.
    4. Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase.
    5. Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise.
    6. Display and print of all kinds of trend chart. Mainly including: HR, BP, METS, HR*BP, exercise trend, ST segment level/influence/slope/3D/J level and ST/HR, etc.
    7. Dynamic/static review function after exercise, representation of the whole exercise testing process.
    8. Case Import/Export function. Compress the case for storage, which takes up less disk space. The compressed case shall be associated with the file type in operation system. This will make the import operation much more simple and quick.
    9. System setting function includes multiple setting items. For example, switching Chinese/English language, format and mode of displaying waveform (12 leads * 1column / 6leads * 1column / 6leads * 2columns / 3leads * 2columns / 3 leads * 1column, etc), color of background, print related setting, filter setting and displaying of optional parameters, etc.
    10. Provide multiple functional tools, which are used for device management, cases statistics and other operations.
    11. Wireless mode of ECG data sampling, improves the anti-interference capability.
    12. Supportive for variety types of exercise equipment
    Performance
    Patient leak current: <10µA
    Input impedance: ≥50MΩ
    Frequency response: 0.05Hz~150Hz (-3dB~+0.4dB)
    Time constant: ≥3.2s
    Common mode rejection ratio (CMRR):>60dB, >100dB (filter on)
    Calibration voltage: 1mV
    Sampling frequency: max. 1000 Hz
    Sampling accuracy: max. 24bits
    Input loop current: ≤50nA
    Polarization resistance voltage: ±500mV
    Noise level: ≤15µVp-p
    Safety type: internally powered equipment, type BF
    Accessories
    Wireless network card 1pc
    Lead cables 1pc
    Electrodes 1pc
    Grounding wire 1pc
    Velcro 2pcs
    Serial-port cable 1pc
    CD 1pc
    Software dog 1pc
    Serial-port card 1pc
    Physical Characteristic
    Dimension: 94mm(L) *66mm(W)*31mm(H)
    Weight: about 94.6g (without battery)
    Option configuration:
    Treadmill  weight: 240kg      USD3000
    Our software can connect with the following brand treadmill:
    § RAM 770                        Italy
    § Track Master 425            USA
    § Paeha                            Korea
    § LODE VALIANT               Netherlands
    Buy safe products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved
    International Buyer--Please note:
    Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
    We are the manufacturer of medical equipment for 17 years, the following are our main products:
    ECG /  ECG holter   EEG / EEG Holter      B-ultrasound
    Patient Monitor      Fetal doppler             Fetal Monitor
    Spo2 Monitor          Stethoscope              Medical Image....
    Agent in the world!
    We are look for partners in the world now!
    Do you want  to become our agent in you conutry?
    Join US!
    Skype:xuebox3
    contec.med.mary at hotmail.com
    Only English User Manual,Please contact us if you need other language version.thank you